Catalogues

BlockBuster® Laryngeal Mask Airway

Tuoren has the innovative product called BlockBuster® Laryngeal Mask Airway device that helps to open patients’ airways at the time of unconsciousness. It is a specific kind of supraglottic airway instrument. In the pre-hospital situation (such as by paramedics and emergency medical technicians), they are most frequently employed by anaesthetists to deliver oxygen or inhalational anesthetic to the lungs during surgery.

BlockBuster®  Laryngeal Mask Airway - Tuoren

In contrast to tracheal tubes, which pass through the glottis, a laryngeal mask is made up of an airway tube that connects to an elliptical mask with a cuff that is passed through the patient's lips, down the windpipe, and when deployed forms an airtight seal on top of the glottis.

Difficult Airway might result in failure of intubation or serious complications. Supraglottic airway devices are suggested.

Features


  • Four-way connector makes it easy to fix after placement.
  • Integrated bite block prevents airway occlusion.
  • Sputum collection device can collect small quantity of sputum.
  • The design of inlet and outlet of gastric access channel is easy for gastric tube insertion.
  • Airway tube: More than 95 degree angulated short airway tube provides easy insertion and matches oropharyngeal curve.
  • Guidance device allows ET Tube to direct towards laryngeal opening at 30-degree angle, which enhances success rate of endotracheal intubation.

Clinical Usage:

  • If tracheal intubation or Anesthesia mask fails, supraglottic airway devices are recommended
  • Same function with normal Laryngeal Mask
  • Directly use a laryngeal mask or take it as a channel for ETT exchange
  • A channel for checking with fiberscope or treatment

Technical Parameters


Name

Type

Applicable Patient Weight

Volume of Air

Blockbuster ETT?ID?

Bronchoscope

Gastric Tube

Blockbuster®

Laryngeal Mask

1#

?5kg

4ml

3.5mm

2.8mm

6Fr

1.5#

5kg-10kg

7ml

4.0mm

3.0mm

8Fr

2#

10kg-20kg

10ml

5.0mm

3.0mm

10Fr

2.5#

20kg-30kg

14ml

5.5mm

3.0mm

12Fr

3#

30kg-50kg

20ml

7.0mm

5.7mm

16Fr

4#

50kg-70kg

30ml

7.5mm

5.7mm

16Fr

5#

70kg-100kg

40ml

8.0mm

5.7mm

16Fr

 

Product Features:

  • Flexometallic Tube body, kink-resistance, easy to be shaped and extracted.
  • Self-guiding function which improves the success rate of intubation without or with a LMA Blockbuster.
  • Parker Pen Tip should be atraumatic, flexible, curved, centred, tapered distal tip geometry that is designed to facilitate rapid, easy, non-traumatic intubation.
  • If used with Our Blockbuster LMA for intubation, success rate of intubation is greater than 95%, also known as blind intubation.